Название | Isotopic Constraints on Earth System Processes |
---|---|
Автор произведения | Группа авторов |
Жанр | |
Серия | |
Издательство | |
Год выпуска | 0 |
isbn | 9781119594963 |
Figure 2.1 Alkali‐silica diagram showing the coordinates of the two starting materials used in the diffusion couple experiments.
2.2.2. Electron Microprobe Analyses
Each diffusion couple was extracted and sectioned down its vertical axis, mounted in a 1‐inch epoxy puck, and polished to 0.25 μm. After mounting, we measured the length of the diffusion couples and note that each one had compressed from an initial length of 10.4 mm down to about 6.6 mm. Axis‐parallel major‐element diffusion profiles were measured from end‐to‐end with a JEOL JXA‐8200 SuperProbe at Lawrence Livermore National Laboratory using a 15 nA beam current rastered at 12000× magnification (12 μm × 9 μm beam dimensions) with an accelerating voltage of 15 kV. Sodium was measured first at each spot to mitigate effects of Na migration. All electron probe data are provided as an Excel file in the Electronic Supplement.
2.2.3. Ca Isotopic Measurements
After microprobe measurements, diffusion couples were sectioned into wafers, about 465 μm thick and weighing about 3 mg, using a Bico diamond wafer saw with blade thickness of 165 μm. The wafers were dissolved in a mixture of hydrofluoric and perchloric acid, dried at 165°C, redissolved in 5 mL 3N HNO3, aliquotted, mixed with a 42Ca‐48Ca double spike to correct for spectrometer‐induced mass discrimination (cf. Watkins, 2010), dried to a small bead, and the bead was redissolved in 100 μL 3N HNO3 for loading onto cation exchange columns. The Ca fraction was separated and collected by cation exchange chromotography using Eichrom Ca‐spec DGA resin. The non‐Ca fraction was saved for subsequent K isotope work. About 3 μg of purified Ca from each sample were loaded onto a zone‐refined Re filament, dried down, topped with 1 μL of 20% of H3PO4 acid and re‐dried.
Ca isotopes were measured by thermal ionization mass spectrometry (TIMS) at UC‐Berkeley on a Thermo‐Finnegan Triton TI with nine moveable Faraday collectors. For each sample, at least 100 isotope ratio measurements were made to reduce within‐run uncertainties to ± 0.04‰. At the time these data were collected in 2009, the long‐term uncertainty in the standard (SRM 715) was conservatively estimated to be ± 0.15‰, and we use this value for the error bars. The Ca isotope ratios of the samples were determined using an iterative spike subtraction algorithm and are reported as (Skulan et al., 1997):
(2.1)
The Ca isotope compositions are provided in Table 2.2.
Figure 2.2 Piston‐cylinder sample assembly used for the diffusion couple experiments. All dimensions are in millimeters.
2.2.4. K Isotopic Measurements
Potassium was separated for isotopic analysis from the sample solutions after Ca separation using columns loaded with 1.8 ml of AG30x8 cation resin. Sample aliquots with ∼600 ng K were dried down, taken up in 300 μL of 1 M HNO3, loaded on the columns, eluted with 1 M HNO3, and the K fraction was collected (Bourg et al., 2010). After drying the separated K solutions down, the K residue was brought up in 0.3 N HNO3 to a concentration of 400 ppb. The 41K/39K ratios of the separated K were measured using a multi‐collector ICP sourced mass spectrometer (IsoProbe, GV Instruments Ltd.) at Lawrence Berkeley National Lab. The IsoProbe is equipped with a RF hexapole ion‐guide that allows the introduction of gasses to provide both energy focusing as well the removal of isobaric interferences arising from Ar ions. In the case of the K isotopic measurements reported here, He and H2 were introduced to the hexapole region at rates of 10 mL/min and 1 mL/min, respectively, to suppress mass interferences from Ar isotopes. For K isotopic measurements, a standard‐sample bracketing technique was employed using an in‐house K reference (K spectroscopic standard, ULTRA Scientific) matching the sample unknowns in concentration (Christensen et al., 2018). The potassium isotopic composition is reported as:
Table 2.2 Summary of isotopic results.
Sample | Distance (mm) | δ 44Ca | n | δ 41K | n |
---|---|---|---|---|---|
RP2–1 | 0.33 | 0.70 | 2 | – | – |
RP2–2 | 0.99 | 0.46 | 5 | – | – |
RP2–3 | 1.65 | 0.15 | 4 | – | – |
RP2–4 | 2.31 | –0.37 | 2 | – | – |
RP2–5 | 2.97 | –0.77 | 2 | – | – |
RP2–6 | 3.62 | –0.90 | 2 | – | – |
RP2–7 | 4.28 | –1.26 | 2 | – | – |
RP2–8 | 4.94 | –0.78 | 2 | – | – |
RP2–9 | 5.60 | –0.78 | 2 | – | – |
RP2–10 | 6.26 | – | – | – | – |
RP3–1 | 0.33 | –0.42 | 3 |
|