band filter.

      Solution

      1/12-octave filters are obtained by dividing each one-octave band into 12 geometrically equal sub‐sections, i.e. fU/fL = 21/12. By the same procedure as for octave and one‐third‐octave filters, we get the result that for 1/12‐octave bands the cutoff frequencies, fL and fU, are fC × 2−1/24 and fC × 21/24, respectively. Then, the bandwidth is given by Δf = fUfL = fC(21/24 − 2−1/24), so Δf ≈ 6% (fC).

      On the other hand, instruments for constant bandwidth filter analysis are normally constructed so that the center frequency of a single filter can be tracked effectively throughout the frequency range of interest. Often different bandwidth settings are available on the same instrument (e.g. 1, 5, 10, 20 Hz). The narrower the bandwidth chosen, the slower the tracking rate should be to obtain reliable results. A rule which should be used in spectrum analysis is that the duration, T, of the noise sample length (or of the analysis time) must be at least as long as the reciprocal of the bandwidth Δf,

      (1.16)equation

      This fundamental principle, also known as the uncertainty principle, puts a limit on the corresponding resolutions in the time and frequency domain, meaning that narrow resolution in one domain means wide resolution in the other domain [10].

      If fine frequency resolution is not needed or if the signal is broadband in nature, then octave band readings are sufficient. One‐third octave band readings (or narrower) should be used if the signal spectrum is not smooth or if pure tones are present. For diagnostic work on machinery, it may be necessary to use constant bandwidth filters (e.g. if the fan blade passing frequency and its higher harmonics must be separated).

Schematic illustrations of the comparison between bandwidths of (a) constant percentage and (b) constant bandwidth filters at the same frequency. Schematic illustration of a simplified block diagram of a parallel-filter real-time analyzer.

      Although equipment for analyzing noise and vibration signals with constant frequency bandwidth filters and constant percentage bandwidth (CPB) filters are still available, these instruments have largely been replaced by Fast Fourier Transform (FFT) Digital Fourier analyzers. These types of analyzers give similar results in a fraction of the time and at a lower cost. These Fourier analyzers are manufactured by several companies and make use of the FFT algorithm which was published by Cooley and Tukey in l965 [18]. This algorithm is much faster than conventional digital Fourier transform algorithms and has made the digital FFT analyzer a useful, efficient means of signal analysis [19].

      In digital FFT analyzers, the analog signal needs to be converted to digital. The signal is not only sampled discretely in time but quantized as well with discrete amplitude values. Because of sampling, the digital system is limited in frequency, which may cause some problems, such as aliasing. During the sampling process, the amplitude of each sample is represented and stored as finite binary numbers in a computer. Rounding errors produce a signal‐correlated noise, called quantization noise, which is another disadvantage of the digital system. So the sampling rate and resolution are two basic considerations of the ADC [20].

      FFT analyzers operate on discrete blocks of data where each sample block is captured then analyzed while the next block is being captured, and so on. Unlike equipment which works on purely analog or hybrid analog/digital principles, the digital FFT analyzer makes all the analysis digitally. Since all the analysis results are in digital form, numerous calculations can be performed by such analyzers. The Fourier transform X(f) of a time signal x(t) may be calculated (see Eq. (1.6)). In addition, the auto‐power spectral density Gx(f) (Eq. (1.15)) may be calculated. A dual‐channel FFT analyzer is able to sample two input signals simultaneously and compute several joint functions. This type of analyzer is widely used in modal testing, electroacoustics, and vibroacoustics applications. If two signals x1(t), x2(t) are fed into the computer at once, then the cross‐spectral density G12(f) can be calculated [12, 13],

      (1.17)equation

      In general G12(f) is a complex quantity having both an amplitude and a phase. The phase is the relative phase between the two signals. The real and imaginary parts of the cross‐spectrum are referred to as the co‐spectrum and quad‐spectrum, respectively. The auto‐power spectral densities

      (1.18)equation

      (1.19)equation

      are real quantities.

      If x1(t) were an input (for example, a measured force) and x2(t) an output (for example, a measured displacement), then the transfer function H12(f) can be computed [5, 13],

      (1.20)equation