As a monitor of respiratory function, capnography is superior to pulse oximetry because it changes nearly immediately with changes in ventilation. On the other hand, hypoxia may be delayed by the body’s reserve and the physiology of hemoglobin oxygen dissociation, as discussed above. When capnography waveform analysis is included, a near real‐time assessment is possible and EMS clinicians may identify inadequacy of ventilation or the presence of various respiratory disease states, and they may glean information about circulatory and metabolic function as well.
Impairment of ventilation is associated with rising EtCO2 values. When combined with waveform analysis, respiratory effort may also be monitored as to rate and depth of breathing. When respiratory rate or respiratory depth has become inadequate and EtCO2 values rise, clinicians can initiate or augment respiratory support prior to the development of hypoxia. In the prehospital environment, this application of waveform capnography is especially useful in monitoring respiratory status following the administration of opioid analgesics, benzodiazepines, and other medications capable of producing respiratory depression (Figure 6.2).
Box 6.2 Factors that affect EtCO2
True decrease in blood PaCO2:
Hyperventilation (primary or secondary)
Shock/cardiac arrest (with constant ventilation)
Hypothermia /decreased metabolism
True increase in blood PaCO2:
Hypoventilation
Return of circulation after cardiac arrest
Improved perfusion after severe shock
Tourniquet release
Administration of sodium bicarbonate
Fever/increased metabolism
Thyroid storm
Increased gap between blood PaCO2 and EtCO2:
Severe hypoventilation
Increased alveolar dead space
Decreased perfusion
Disconnected or clogged tubing
Figure 6.2 Capnography waveforms. (a) Normal waveform. Point A is beginning of expiration. A‐B is expiration of dead space air. B‐C shows rapid rise in level of CO2 as air from lungs is exhaled. C‐D is the plateau phase representing primarily alveolar air. D represents the value used for determination of EtCO2. D‐A represents inspiration. (b) Effect of bronchospasm. Note the slower rise in the CO2 level leading to the so‐called shark fin waveform. (c) Hypoventilation. (d) Hyperventilation
Obstructive respiratory physiology is the most often described diagnosis made upon EtCO2 waveform analysis. Both chronic obstructive pulmonary disease (COPD) and asthma fall into this category, and the waveform produced will be similar. The classic description of this waveform is the “shark fin” morphology, consisting of a shallower upward sloping of the initial rise of the EtCO2 wave (Figure 6.2b). This represents a slower rate of exhalation. It may be considered analogous to the forced expiratory volume in one second measurement of the pulmonary function test. This slower exhalation is precipitated by collapse or partial occlusion of bronchioles in emphysema and chronic bronchitis and spasm in acute asthma attacks. As the condition improves following bronchodilation, the initial upward segment will become more vertical. However, in more severe cases, the numeric value or amount of EtCO2 will also rise, heralding respiratory insufficiency, and should lead the clinician to consider ventilatory support measures.
Although less commonly employed, EtCO2 and waveform analysis may also be useful in assessment of metabolic derangements such as diabetic ketoacidosis and aspirin overdose. These conditions cause respiratory compensation of metabolic acidosis and will present with hyperventilation, typically with a decreasing level of EtCO2.
Assisting Oxygenation and Ventilation
While oxygenation and ventilation are distinct parameters, their assessment and management are often interdependent. Thus, we discuss them together.
The initial and most basic treatment for inadequate oxygenation is the administration of supplemental oxygen to increase the relative amount, or fraction, of oxygen in inspired gases (i.e., FiO2). Oxygen should be provided to all patients with respiratory distress, with any clinical markers of respiratory compromise (e.g., altered mental status), or with measured inadequate oxygenation or ventilation. There is an increasing trend toward more selective application of oxygen with the growing recognition of oxygen toxicity. Most current guidelines and protocols endorse administering supplemental oxygen only if the oxygen saturation is less than 94%. Unnecessarily elevating the SpO2 above normal levels may in fact be harmful to patients experiencing neurological or cardiac insults associated with ischemic damage [7].
Patients with underlying pulmonary disease, such as COPD and interstitial fibrosis, may have oxygen saturations below 94% on a chronic basis. A subset of these patients will also have chronically high PaCO2 levels (hypercapnia), which lead to dependence on a hypoxic drive for ventilatory control and stimulation. Providing supplemental oxygen, especially at high flow rates, may contribute to respiratory depression and potentially produce apnea [8]. EMS clinicians must carefully assess and monitor these patients, administer oxygen if needed, and be prepared to assist ventilation. Oxygen should not be withheld from a hypoxic patient because of concern for their dependency on a hypoxic drive for breathing.
Supplemental oxygen can be administered through various devices that deliver different ranges of oxygen concentration (Table 6.2). Most EMS systems carry nasal cannulas and non‐rebreather facemasks, allowing clinicians to choose either a lower or a higher FiO2. When supplemental oxygen itself does not lead to adequate oxygenation of blood, noninvasive positive‐pressure ventilation (NIPPV) can be beneficial to supplement ventilatory function in addition to providing increased FiO2. This modality is most effective in patients with pulmonary edema, who have poor oxygen diffusion between alveolar air and the pulmonary capillary blood. Further, it is useful for patients with other conditions, including asthma, COPD, and pulmonary hypertension. NIPPV is described in more detail below.
Table 6.2 Devices for delivery of supplemental oxygen
Device name | O2 flow rate (L/min) | FiO2 (approximate %) |
---|---|---|
Nasal cannula
|