Название | Interpretation Basics of Cone Beam Computed Tomography |
---|---|
Автор произведения | Группа авторов |
Жанр | Медицина |
Серия | |
Издательство | Медицина |
Год выпуска | 0 |
isbn | 9781119685876 |
DDS, MS, Diplomate, American Board of Oral and Maxillofacial Radiology with invited Contribution from Gayle Tieszen Reardon
This edition first published 2021
© 2021 John Wiley & Sons, Inc.
Edition History John Wiley and Sons Inc (1e, 2014)
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, except as permitted by law. Advice on how to obtain permission to reuse material from this title is available at http://www.wiley.com/go/permissions.
The right of Shawneen M. Gonzalez to be identified as the author of the editorial material in this work has been asserted in accordance with law.
Registered Office John Wiley & Sons, Inc., 111 River Street, Hoboken, NJ 07030, USA
Editorial Office 111 River Street, Hoboken, NJ 07030, USA
For details of our global editorial offices, customer services, and more information about Wiley products visit us at www.wiley.com.
Wiley also publishes its books in a variety of electronic formats and by print‐on‐demand. Some content that appears in standard print versions of this book may not be available in other formats.
Limit of Liability/Disclaimer of Warranty The contents of this work are intended to further general scientific research, understanding, and discussion only and are not intended and should not be relied upon as recommending or promoting scientific method, diagnosis, or treatment by physicians for any particular patient. In view of ongoing research, equipment modifications, changes in governmental regulations, and the constant flow of information relating to the use of medicines, equipment, and devices, the reader is urged to review and evaluate the information provided in the package insert or instructions for each medicine, equipment, or device for, among other things, any changes in the instructions or indication of usage and for added warnings and precautions. While the publisher and authors have used their best efforts in preparing this work, they make no representations or warranties with respect to the accuracy or completeness of the contents of this work and specifically disclaim all warranties, including without limitation any implied warranties of merchantability or fitness for a particular purpose. No warranty may be created or extended by sales representatives, written sales materials or promotional statements for this work. The fact that an organization, website, or product is referred to in this work as a citation and/or potential source of further information does not mean that the publisher and authors endorse the information or services the organization, website, or product may provide or recommendations it may make. This work is sold with the understanding that the publisher is not engaged in rendering professional services. The advice and strategies contained herein may not be suitable for your situation. You should consult with a specialist where appropriate. Further, readers should be aware that websites listed in this work may have changed or disappeared between when this work was written and when it is read. Neither the publisher nor authors shall be liable for any loss of profit or any other commercial damages, including but not limited to special, incidental, consequential, or other damages.
Library of Congress Cataloging‐in‐Publication Data
Names: Gonzalez, Shawneen, author, editor.
Title: Interpretation basics of cone beam computed tomography / edited by Shawneen M. Gonzalez.
Description: Second edition. | Hoboken, NJ : Wiley‐Blackwell 2021. | Includes bibliographical references and index.
Identifiers: LCCN 2021028942 (print) | LCCN 2021028943 (ebook) | ISBN 9781119685845 (hardback) | ISBN 9781119685852 (adobe pdf) | ISBN 9781119685876 (epub)
Subjects: MESH: Cone‐Beam Computed Tomography. | Radiography, Dental–methods. | Craniofacial Abnormalities–diagnosis. | Facial Bones
Classification: LCC RC78.7.T6 (print) | LCC RC78.7.T6 (ebook) | NLM WN 230 | DDC 616.07/5722–dc23
LC record available at https://lccn.loc.gov/2021028942 LC ebook record available at https://lccn.loc.gov/2021028943
Cover Design: Wiley
Cover Image: © Shawneen M. Gonzalez
Preface to the Second Edition
It is the goal of this book to help practitioners and students gain a better understanding of anatomy and common disease processes that frequently present on cone beam computed tomography (CBCT) scans. This book seeks to fill the gap in the current literature where little is presented on common radiographic appearances on CBCT. In addition to this book, there are sample cases with videos online at www.wiley.com/go/gonzalez/interpretation, where you can practice working your way through regions and entire scans using the knowledge you acquire in this book.
The beginning of the book covers general information about different CBCT unit parameters and recommended uses from specialty organizations. The third chapter covers legal considerations of owning a cone beam CT, referring patients for a cone beam CT scan, and/or interpreting cone beam CT scans in the United States. This information is lacking in the current literature and is something many professionals should be aware of before purchasing or using a cone beam CT unit.
Each book chapter from the fourth chapter on is an anatomical region covering the topics of anatomy, common anatomic variants/developmental anomalies, pathosis, and other findings. The first regions presented are the paranasal sinuses and mastoid air cells and nasal cavity and airway, which are intimately involved with each other. The anatomy section covers pertinent anatomy to evaluate when interpreting or reviewing a scan. The next section covers common anatomic variants with various images showing how they appear on axial, coronal, and sagittal views. The last section covers commonly seen disease processes, such as sinusitis, that should be noted on a written radiology interpretation.
Chapter 6 is on the cranial skull base and orbits. There are many anatomical landmarks in the cranial skull base such as canals, foramina, air cells, and more, making this a difficult region to interpret. Key anatomy is shown on various views (axial, coronal, and sagittal) to aid CBCT users in orienting themselves on the scan.
All soft‐tissue findings are moved into one chapter. There is no anatomy as CBCT is a hard‐tissue imaging modality. All findings are listed as pathosis or other findings and appear as calcifications in the soft tissues.
The region of the cervical spine covers anatomy to disease processes such as degenerative joint disease. Degenerative joint disease is progressive with multiple appearances based on the degree of bony damage. This chapter has many example images of degenerative joint disease at various points in the disease process.
The last region covered is the temporomandibular joints, which is very thorough thanks to the contributions of Gayle Reardon, who has studied and continues to study this region in depth. The temporomandibular joints have a unique set of disease processes and developmental appearances beyond arthritic changes. This chapter covers entities CBCT users should be aware of even if they are not seen in daily practice.
The appendix shows example written reports of CBCT scans to view and consider when writing radiology interpretations.
Acknowledgments