Название | EXTREMOPHILES as Astrobiological Models |
---|---|
Автор произведения | Группа авторов |
Жанр | Физика |
Серия | |
Издательство | Физика |
Год выпуска | 0 |
isbn | 9781119593102 |
Table 1.1 Fumarole sampling locations and physical properties.
Location | pH | Temp (°C) | Type | Chemistry |
Hawai’i Volcanoes National Park1 | ||||
Hawai’i (1) | 5.5 | 65.0 | Cave | Nonsulfur |
Hawai’i (2) | 5.2 | 68.0 | Cave | Nonsulfur |
Hawai’i (3) | 3.0 | 82.0 | Cave | Sulfur |
Hawai’i (4) | 3.0 | 82.0 | Cave | Iron/sulfur |
Hawai’i (5) | 5.0 | 68.0 | Cave | Salt |
Hawai’i (6) | 4.5 | 66.0 | Cave | Salt/sulfur |
Lassen Volcanic National Park2 | ||||
Sulphur Works, lower (1) | 4.5 | 87.0 | Cave | Nonsulfur |
Sulphur Works, lower (2) | 3.2 | 93.0 | Vent | Sulfur |
Sulphur Works, lower (3) | 4.0 | 91.5 | Cave | Sulfur |
Sulphur Works, upper (4) | 3.0 | 85.5 | Vent | Iron |
Sulphur Works, upper (5) | 2.5 | 81.2 | Cave | Iron |
Valles Caldera National Preserve3 | ||||
Sulphur Springs, New Mexico | 2.0 | 89.0 | Cave | Nonsulfur |
Pozzuoli, Italy4 | ||||
Solfatara Crater | 3.0 | 94.0 | Vent | Sulfur |
1 June 2016 sampling
2 Oct 2018 sampling
1.3.1 Steam Collection
Samples of steam were collected from fumaroles in four permanently protected geothermal areas, Lassen Volcanic National Park, Hawai’i Volcanoes National Park, Valles Caldera National Preserve, and Solfatara Crater, Italy. Our steam collector (Figure 1.1) consists of a stainless shroud with a central holder for the sample tube. The condenser with a splash shield fits into the shroud and is slightly raised at 3 points, allowing excess steam to bypass the edges of the condenser during collection. The central lower guide rod directs condensed steam water into a sterile 50 mL polypropylene tube. During steam collection the open tube rests in a holder attached near the bottom of the shroud. The steam condenser can be handheld, but is also used attached to a tripod by an external mount, which by design serves to protect samples from aerial contaminants. During collection, rising steam contacts the water-cooled condenser and the guide rod drains the condensed steam water directly into the collection tube. After collection, the tube is immediately capped. Overall, the unit is portable, durable, corrosion resistant, easily autoclaved and produces contamination-free steam condensed samples and controls in a relatively short time period. In an average collection a 20–25 mL sample is collected in 15 min. Faster collections occur with