Название | Agitator Design for Gas-Liquid Fermenters and Bioreactors |
---|---|
Автор произведения | Gregory T. Benz |
Жанр | Химия |
Серия | |
Издательство | Химия |
Год выпуска | 0 |
isbn | 9781119650539 |
Flooding is a condition in which there is too much gas flowing into an impeller for it to effectively disperse it. If the main purpose of the agitator is to disperse the gas, this is obviously not a desirable condition. But how do we define it quantitatively and how do we measure it? There are actually several ways. We will describe three of them here.
kla Method
By kla, we mean the overall mass transfer coefficient, as defined by:
(4.1)
Figure 4.1 Flooding determination by using kla.
Imagine an agitator operating at zero rpm, with gas being bubbled below the impeller. Although the impeller is not dispersing gas, there will still be some mass transfer possible, and therefore, the value of kla will be non‐zero. As the shaft speed increases, the kla value will remain essentially constant, until a certain threshold speed is reached, at which point the kla value will start increasing rapidly, as shown in Figure 4.1. We would call that threshold speed the flooding emergence point, by one definition. By inspection of Figure 4.1, the flooding emergence point is about 58 rpm.
One could also use mass transfer rate as the y‐axis if the driving force remained constant.
While this definition of flooding has the advantage of clearly defining the point at which the agitator actually begins to influence mass transfer and thus relates to the main purpose for the use of the agitator, it is experimentally difficult to carry out. Most published definitions and correlations of flooding do not use this method, as we will see. This method does, however, have the advantage of being possible to carry out in an opaque vessel.
Power Draw Method
When gas is introduced into an impeller, it lowers power consumption, as will be described later in more detail. However, in many cases, the power draw increases when flooding, especially for Rushton or other impellers with flat vertical blades. This is due to the loss of gas pockets which streamline flow, illustrated in Chapter 5. This can be used as an indication of flooding, as illustrated in Figure 4.2
However, this phenomenon does not occur at all Froude numbers and can be difficult to detect for deeply concave impellers, as they have little or no gas pockets to streamline flow. For such impellers, the gassing factor is mostly a density reduction factor, which might not change much due to flooding. An opaque vessel will work for this method also.
Figure 4.2 Impeller flooding by power draw.
Visual Flow Pattern Method
The most common method of defining and determining flooding is the visual method. It is the method upon which all flooding equations in this book are based. Referring to Figure 4.3, flooding emergence occurs when the bubble flow and dispersion pattern changes from condition (a) to condition (b). This is easily observed in a transparent vessel and is a very repeatable condition. In condition (b), the bubbles are driven to the vessel wall, more or less in the plane of the impeller. This a somewhat conservative definition of flooding, as mass transfer enhancement actually begins before the bubbles are fully driven to the wall. It actually begins when the bubbles are driven even a short distance off a vertical path, as long as the impeller Froude number is at least 0.03 for Rushton turbines (the minimum Froude number may be somewhat lower for concave and deeply concave impellers, but the author is unaware of studies conducted below a Froude number of 0.03.)
Condition (c) in Figure 4.3 is called complete dispersion. It occurs when gas is driven to the bottom of the tank and some of it is recirculated into the impeller. It is not a design condition per se, but usually occurs when agitation is sufficient to support medium and high mass transfer rates (for example, above 80 mmol/l‐h for an air‐based fermentation at a back pressure of 1 bar‐g or less.)
The transitions from condition (a) through condition (c) can be thought of as either increasing shaft speed at constant airflow or decreasing airflow at constant shaft speed.
Figure 4.3 Visual flooding.
The above definitions work well for radial flow impellers, which are most commonly used as the primary disperser. Some systems use only axial flow impellers. There is no standard definition of flooding for these. The kla method could be used, whether the impellers are up or down pumping. It would be difficult to use the visual method for an up‐pumping system. For down pumping, there is a transition from direct loading (the gas goes through the impeller on the way up) to indirect loading (the gas is driven out of the impeller’s path by its discharge velocity, and some gas is recirculated into the impeller from above). We do not have a figure to illustrate this. But this transition could be a sort of flooding definition.
Effect on Power Draw
As mentioned in the first section on flooding, when gas is introduced to a liquid, it affects power draw. At very low gas rates, some impellers actually have an increased power draw. Likely, this is due to increasing the discharge head imposed on the impeller. But at most gas flowrates used in fermenters and bioreactors, gas causes the power to drop.
There are two causes for this drop. One is that some of the gas is entrained, or held up, in the liquid, causing its apparent density to decrease. Remember, from the power number definition, power draw is directly proportional to fluid density. The other cause is that gas pockets may form along the backside of impellers, streamlining the flow, and reducing drag. For flat‐blade turbines, such as the Rushton, this is the major cause of power draw reduction. For deeply concave impellers, the gas pockets are greatly reduced or even eliminated. Pockets also tend to be smaller on axial flow impellers. We will illustrate these pockets in Chapter 5 under each impeller. For now, note that the gassing factor for deeply concave impellers is usually between 0.85 and 1.0, whereas for Rushton impellers, it can be as low as 0.3. Axial flow impellers generally have gassing factors between these ranges.
Holdup
When gas is dispersed into liquids, it does not rise to the surface instantly. Smaller bubbles take longer to discharge at the surface than larger ones. High power/volume produces smaller bubbles, on average. And the more gas is introduced, the more that will be present in the broth at any given moment. Moreover, as the agitation gets stronger, there is more recirculation of bubbles. All of these things contribute to gas holdup.
From a fluid property point of view, surface tension, ionic strength,